Indications:

  • Fractures of Distal Fibula, Including those in the Metaphyseal and Diaphyseal Regions.
  • Osteotomies of the Distal Fibula.
  • Nonunion & Malunion of the Distal Fibula.

Description

Following Screws are to be use with above Plates:

A) Variolock 2.4mm Locking Head Screw – Self Tapping

Stainless SteelHex DriveTitanium
Cat No.SizeCat No.
–10mm To 30mmTi.100.910 To Ti.100.930
Stainless SteelStar DriveTitanium
Cat No.SizeCat No.
–10mm To 40mmTi.100.810 To Ti.100.840

B) 2.4mm Locking Head Screw – Self Tapping

Stainless SteelHex DriveTitanium
Cat No.SizeCat No.
–10mm To 30mmTi.100.010 To Ti.100.030
Stainless SteelStar DriveTitanium
Cat No.SizeCat No.
–22mm To 40mmTi.101.222 To Ti.101.240

C) 2.4mm Cortical Screw – Self Tapping

Stainless SteelHex DriveTitanium
Cat No.SizeCat No.
–10mm To 30mmTi.100.210 To Ti.100.230
Stainless SteelStar DriveTitanium
Cat No.SizeCat No.
–10mm To 40mmTi.100.510 To Ti.100.540

D) 2.7mm Cortical Screw – Self Tapping

Stainless SteelHex DriveTitanium
Cat No.SizeCat No.
–6mm To 40mmTi.101.106 To Ti.101.140
Stainless SteelStar DriveTitanium
Cat No.SizeCat No.
–10mm To 40mmTi.101.710 To Ti.101.740

E) Variolock 2.7mm Locking Head Screw – Self Tapping

Stainless SteelHex DriveTitanium
Cat No.SizeCat No.
–10mm To 40mmTi.101.910 To Ti.101.940
Stainless SteelStar DriveTitanium
Cat No.SizeCat No.
–10mm To 40mmTi.100.710 To Ti.100.740

F) 2.7mm Locking Head Screw – Self Tapping

Stainless SteelHex DriveTitanium
Cat No.SizeCat No.
–10mm To 50mmTi.101.310 To Ti.101.350
Stainless SteelStar DriveTitanium
Cat No.SizeCat No.
–10mm To 50mmTi.101.410 To Ti.101.450

Following Instruments to be use with above Plate:

Cat No.Description
260.210Drill Bit – S.S. – Quick Coupling End Dia. 2.0mm X 140mm Long
260.215Drill Bit – S.S. Quick Coupling End Dia. 2.2mm x 150mm Long – Calibrated
263.020Bone Tap with T – Handle Dia. 2.7mm Thread Length 33mm, Total Length 125mm
263.023Bone Tap With T – handle For 2.4mm Cortical Screw – S.S.
301.124Hexagonal Screw Driver with Self Holding Sleeve 2.0mm Tip (for 2.4mm Cortical, Locking & 2.7mm Locking Head Screw) – Silicon Handle
301.125Hexagonal Screw Driver with Self Holding Sleeve 2.5mm Tip (for 3.5mm Cortical & 4.0mm Cancellous Screw) – Silicon Handle
301.108Hexagonal Screw Driver  2.0mm Tip – Sillicon Handle
301.110Small Hexagonal Screw Driver 2.5mm Tip – Sillicon Handle
311.004Mini Depth Gauge(Measuring length 40mm)
804.120LCP Drill Sleeve 2.7mm for 2.0mm Drill Bit
804.122Tap for 2.7mm Locking Head Screws
804.123Tap for 2.4mm Locking Head Screws
804.124Variable Angle Drill Sleeve 2.7mm
804.127Conical Type Variable Angle Drill Sleeve 2.7mm
804.162Q.C. Torque Screw Driver Handle 2.0mm Tip (Torque 0.8N.m)
804.166Hexagonal Screw Driver Q.C. End Shaft, 2.0mm Tip(For Torque Handle 0.8N.M)
XP.301.080Star Drive Screw Driver 2mm Tip/T-8

Following Size of Variolock Locking Variable Angle Distal Fibula Plate 2.4/2.7mm is available in Titanium Material:

Cat No. (Left)HolesCat No. (Right)
Ti.843.0033Ti.843.103
Ti.843.0044Ti.843.104
Ti.843.0055Ti.843.105
Ti.843.0066Ti.843.106
Ti.843.0077Ti.843.107
Ti.843.0088Ti.843.108
Ti.843.0099Ti.843.109
Ti.843.01010Ti.843.110
Ti.843.01111Ti.843.111
Ti.843.01212Ti.843.112